Meds & supplements › Oxyquinoline
Medicine · Radioactive Diagnostic Agent
Indium In 111 Oxyquinoline Solution is indicated for radiolabeling autologous leukocytes.
Selected manufacturer label information, organised into consistent sections by Sofidex. This source is written for healthcare professionals; ask your pharmacist to explain instructions that are unclear. Read the full label at DailyMed ↗
Indium In 111 oxyquinoline labeled leukocytes may be used as an adjunct in the detection of inflammatory processes to which leukocytes migrate, such as those associated with abscesses or other infection, following reinjection and detection by appropriate imaging procedures. The degree of accuracy may vary with labeling techniques and with the size, location and nature of the inflammatory process.
Indium In 111 oxyquinoline labeled leukocyte imaging is not the preferred technique for the initial evaluation of patients with a high clinical probability of an abscess in a known location. Ultrasound or computed tomography may provide a better anatomical delineation of the infectious process and information may be obtained more quickly than with labeled leukocytes. If localization by these techniques is successful, labeled leukocytes should not be used as a confirmatory procedure. If localization or diagnosis by these methods fails or is ambiguous, indium In 111 oxyquinoline labeled leukocyte imaging may be appropriate.
The recommended adult (70 kg) dose of indium In 111 oxyquinoline labeled autologous leukocytes is 7.4 to 18.5 MBq, 200 to 500 µCi. Indium In 111 Oxyquinoline Solution is intended for the radiolabeling of autologous leukocytes. The indium In 111 oxyquinoline labeled autologous leukocytes are administered intravenously.
Imaging is recommended at approximately 24 hours post injection. Typically, anterior and posterior views of the chest, abdomen and pelvis should be obtained with other views as required.
Aseptic procedures and a shielded syringe should be employed in the withdrawal of Indium In 111 Oxyquinoline Solution from the vial. Similar procedures should be employed during the labeling procedure and the administration of the labeled leukocytes to the patient. The user should wear waterproof gloves during the entire procedure. The patient's dose should be measured by a suitable radioactivity calibration system immediately before administration. At this time, the leukocyte preparation should be checked for gross clumping and red blood cell contamination.
Sensitivity reactions (urticaria) have been reported. The presence of fever may mask pyrogenic reactions from indium In 111 oxyquinoline labeled leukocytes. The possibility of delayed adverse reactions has not been studied.
None known.
The content of the vial of Indium In 111 Oxyquinoline Solution is intended only for use in the preparation of indium In 111 oxyquinoline labeled autologous leukocytes, and is not to be administered directly. Autologous leukocyte labeling is not recommended in leukopenic patients because of the small number of available leukocytes.
Due to radiation exposure, indium In 111 oxyquinoline labeled leukocytes could cause fetal harm when administered to pregnant women. If this radiopharmaceutical is used during pregnancy, the patient should be informed of the potential hazard to the fetus.
Indium In 111 oxyquinoline labeled autologous leukocytes should be used only when the benefit to be obtained exceeds the risks involved in children under eighteen years of age owing to the high radiation burden and the potential for delayed manifestation of long-term adverse effects.
Clumping of cells may produce focal accumulations of radioactivity in lungs which do not wash out in 24 hours and thus may lead to false positive results. This phenomenon can be detected by imaging the chest immediately after injection.
The normally high uptake of indium In 111 oxyquinoline labeled leukocytes by spleen and liver may mask inflammatory lesions in these organs. Labeled leukocytes have been observed to accumulate in the colon and accessory spleens of patients with or without disease.
Chemotaxis of granulocytes deteriorates during storage and loss of chemotaxis may cause false negative scans. The spontaneous release of indium In 111 has been reported to range from about 3% at one hour to 24% at 24 hours [ten Berge, R.J.M., Natarajan, A.T., Hardeman, M.R., et al, Labeling with indium In 111 has detrimental effects on human lymphocytes, Journal of Nuclear Medicine, 24, 615-620 (1983)]. The maximum amount of time recommended between drawing the blood and reinjection should not exceed 5 hours. It is recommended that the labeled cells be used within one hour of preparation, if possible and in no case more than three hours after preparation.
Plasma and red cell contamination impairs labeling efficiency of leukocytes. Hemolyzed blood in labeled leukocytes may produce heart pool activity and should be avoided.
Cell aggregates of various degrees have been reported. Cell labeling techniques and standing of cell preparation may be contributing factors.
Nuclear medicine procedures involving withdrawal and reinjection of blood have the potential for transmission of blood borne pathogens. Procedures should be implemented to avoid administration errors and viral contamination of personnel during blood product labeling. A system of checks similar to the ones used for administering blood transfusions should be routine.
Strict aseptic techniques should be used to maintain sterility throughout the procedures for using this product.
Do not use after the expiration time and date (5 days after calibration time) stated on the label.
The contents of the vial are radioactive. Adequate shielding of the preparation must be maintained at all times.
Indium In 111 Oxyquinoline Solution, like other radioactive drugs, must be handled with care and appropriate safety measures should be used to minimize radiation exposure to clinical personnel. Care should also be taken to minimize radiation exposure to the patient consistent with proper patient management.
Radiopharmaceuticals should be used only by physicians who are qualified by training and experience in the safe use and handling of radionuclides and whose experience and training have been approved by the appropriate governmental agency authorized to license the use of radionuclides.
sofidex [Internet]. Daloreum; c2026. Oxyquinoline; [reviewed 2026 Aug 3; cited 2026 Nov 10]. Available from: https://sofidex.com/patients/medicines/oxyquinoline
sofidex. (2026, August 3). Oxyquinoline. Daloreum. Retrieved November 10, 2026, from https://sofidex.com/patients/medicines/oxyquinoline
Oxyquinoline. sofidex. Reviewed August 3, 2026. Accessed November 10, 2026. https://sofidex.com/patients/medicines/oxyquinoline
The cited date is today’s, because a citation records when you read the page. The reviewed date is when a clinician last checked it.